C&I · liquid cooling

AlphaESS STORION-LC-TB150

The larger LC-series cabinet: 150 kVA PCS, six LFP modules totalling 313.49 kWh, liquid cooling of both battery and inverter, noise ≤ 60 dB. Factory pre-assembled for fast deployment — on site only the foundation, cabling and commissioning remain.

313–627 kWh

from $146/kWh · excl. VAT

AlphaESS STORION-LC-TB150

Technical specifications

Price
Master $148 · Follower $146 · Expansion $146 per kWh excl. VAT · Master 313.49 kWh — $46,397 · Follower — $45,770 · expansion module 313.49 kWh — $45,770
STS cabinet
300 kW — $5,250 · 600 kW — $7,300 · 800 kW — $15,645
Type
AC-coupled · outdoor all-in-one cabinet · liquid cooling
Power
150 kW (150 kVA at 45 °C) · 165 kVA max
Capacity
313.49 kWh per cabinet · with the expansion module — 626.98 kWh per system
Battery
LFP · M166314-S module · 1P312S · 6 modules in series · 700–1,200 V
Charge/discharge
156.7 kW (0.5 P) · cycle life ≥ 8,000 (0.5 P, 25 °C)
AC output
400 V (±15%) · 3L/N/PE · 50/60 Hz · THDu < 3% · max efficiency 98.5%
Overload
110% continuous · 120% for 1 min · 150% for 10 s
Backup
STS up to 20 ms (separate STS cabinet)
Parallel operation
Up to 25 cabinets on-grid
Fire safety
Aerosol + sprinkler + flammable-gas detection · UL 9540A
Dimensions · weight
1,340 × 1,542 × 2,413 mm · up to 3.2 t
Enclosure
IP55 · ≤ 60 dB · −30…+50 °C (derating above 45 °C) · up to 3,000 m (derating above 2,000 m) · Modbus TCP
Certification
IEC 62477 · IEC 61000 · EN 50549 · VDE 4110 · G99 · C10/11 · CEI 0-16 · IEC 61727 · IEC 62116 · IEC 62619 · UL 9540A
Warranty
Per AlphaESS terms — quoted in the proposal

Based on the AlphaESS STORION-LC-TB150 datasheet V1.0 (02.2026); Ultra cycle life, RTE and DoD per AlphaESS materials (ESS Europe 2026). Indicative equipment prices in USD excl. VAT as of October 2026; installation, commissioning and grid connection are quoted in the proposal.

FAQ

How does STORION-LC-TB150 differ from TB125?

In the power and capacity of a single cabinet: 150 kW (165 kVA max) against 125 kW, and 313.49 kWh against 261.2 — six battery modules in series instead of five, battery voltage 700–1,200 V. Liquid cooling covers both the battery and the PCS, which is why the rated noise is ≤ 60 dB. The cabinet is larger: 1,340 × 1,542 × 2,413 mm, up to 3.2 t. The rest of the platform is shared: STS up to 20 ms, up to 25 cabinets in parallel, Modbus TCP, IP55.

How does TB150 scale and what is the battery cycle life?

One cabinet holds 313.49 kWh; with the expansion module — 626.98 kWh per system; up to 25 cabinets in parallel on-grid, i.e. up to about 7.8 MWh. The datasheet rates the battery at 8,000 cycles or more at 0.5 P and 25 °C; according to AlphaESS, the Ultra version is rated up to 12,000 cycles, system RTE is 90% and DoD is 95% on-grid / 90% off-grid, battery packs are IP67 and a C5 anti-corrosion option is available; the enclosure is IP55 (datasheet).

How much does STORION-LC-TB150 cost?

From $146/kWh excl. VAT for the equipment: Master cabinet — $148/kWh, i.e. $46,397 for 313.49 kWh; Follower — $146/kWh, $45,770; expansion module 313.49 kWh — $146/kWh, $45,770. The STS cabinet is $5,250 (300 kW), $7,300 (600 kW) or $15,645 (800 kW). The final budget depends on the number of cabinets, STS and grid-connection works — send your hourly consumption profile and within 2 business days we return a feasibility study with budget and payback.

Other AlphaESS models

Size it for your profile?

Send your hourly consumption profile — we will return a feasibility study with real DAM prices.

Request a proposal→